+86-21-2022-7873
ARTECH TECHNOLOGY CO., LTD.
Professional Manufacturing
Manufacturing - skilled personnel and advanced equipment
Engineering- engineering team with 10+ years experiences
Technology- hard ware with embedded soft program
Warrant - beyond Industry Standard Warranty
General Features
Customized QFP IC
Display: 3 3/4Digit (4000 Counts) LCD display
Auto Range
DCA ZERO
Data hold
Over Range indication
Low battery indication
Auto power off: 15 MIN
Jaw opening : approx. 40mm
Dimension: 190(L)*69(W)*23(H) mm
Power Supply: 3V CR2032*2PCS
Accessories: Rubber boot, Soft Case, Blister & Blister Card package, Test Leads, K-Type Thermocouple, 2pc of Maxell batteries
Specifications
DCV
Ranges
Accuracy
Resolution
400mV
±(0.8%+3)
0.1mV
4V
1mV
40V
10mV
400V
100mV
600V
1V
Input Impedance:10MΩ
Overload Protection:600V rms.
ACV
Input Impedance:10MΩ
Ranges
Accuracy
Resolution
4V
±(1.2%+3)
1mV
40V
10mV
400V
100mV
600V
±(1.5%+3)
1V
Frequency Response: 40~400HzOverload Protection:600Vrms.
DCA
Ranges
Accuracy
Resolution
400A
±(2.0%+3)
100mA
1000A
1A
ACA
Ranges
Accuracy
Resolution
400A
±(2.0%+3)
100mA
1000A
1A
Frequency Response: 50~60Hz
Resistance
Ranges
Accuracy
Resolution
400Ω
±(2.0%+3)
0.1Ω
4KΩ
±(1.0%+3)
1Ω
40KΩ
10Ω
400KΩ
100Ω
4MΩ
1KΩ
40MΩ
±(2.5%+3)
10KΩ
Overload Protection:250Vrms
Frequency
Ranges
Accuracy
Resolution
10Hz
±(0.3%+3)
0.001Hz
100Hz
0.01Hz
1KHz
0.1Hz
10kHz
1Hz
100kHz
10Hz
1MHz
100Hz
10MHz
1kHz
Overload Protection:500Vrms
Sensitivity:1Vrms(10~100kHz), 5Vrms(1MHz~10MHz)
Temp.
Ranges
Accuracy
Resolution
-20~750℃
±(2.0%+3)
1℃
-4~1400℉
±(2.0%+3)
1℉
Continuity Test
In case that the resistance between two tested points is less than 40±5Ω, the buzzer will be sound.
Ranges
Test Condition
Continuity Test
Open-circuit voltage is about 1.0V
Diode Test
Open-circuit voltage is about 3.2V
Overload Protection:250Vrms.
ARTECH TECHNOLOGY CO., LTD.
Copyright © 2008-2014 , www.g-artac.com ,沪ICP备17037637号-1,All rights reserved
Add:No 1, Shanpu Road, Kunshan, Jiangsu Province, China.